Supersedes DEFSTAN 02-749(PT3)/1(2000), DEFSTAN 02-779(PT3)/1(2000), DEFSTAN 02-780(PT3)/1(2000) and DEFSTAN 02-837/2(2005). (08/2011) This standard is obsolescent because it is no longer required for procurement of new equipment but is retained for maintenance purposes in support of existing in-service equipment. (08/2016)
Chemical Element | % Present |
---|---|
Iron (Fe) | 0.60 - 1.00 |
Manganese (Mn) | 0.50 - 1.50 |
Nickel (Ni) | 30.00 - 32.00 |
Copper (Cu) | Balance |
Mechanical Property | Value |
---|---|
Elongation (Min) | 35% |
Proof Stress (Min) | 140 MPa |
Tensile Strength (Min) | 400 MPa |
Mechanical Property | Value |
---|---|
Elongation (Min) | 16% |
Proof Stress (Min) | 400 MPa |
Tensile Strength (Min) | 480 MPa |